Grant Euroflame Condensing Outdoor Module 70/90

Availability:

1,335.00

    • 50 €
    • 0 €
    • 0 €
Quantity:

Product Description

Grant Euroflame A-Rated Condensing 90,0000 BTU Outdoor Module Oil Boiler Complete With Flue Kit

 

FEATURES

  • Model – 70-90
  • Output (BTU) – 70K-90000
  • Output (KW) – 21-26
  • Efficiency – 94.4%
  • Optional side flue exit
  • Optional pipe entry point
  • Riello RDB burner

The Grant Euroflame economical outdoor oil boiler range has been introduced as a direct response to customer demand for a competitively priced free standing economical condensing boiler designed for situations where internal space is at a premium. The Euroflame models incorporate a new version of the Grant Vortex stainless steel heat exchanger and are extremely efficient having achieved an ‘A’ rating on the SEDBUK and HARP databases.

• High efficiency SEDBUK & HARP ‘A’ Rating
• Features a Riello RDB Burner
• Whisper quiet operation
• Optional pipe entry points
• Comes complete with a factory fitted multi-directional flue
• Optional side or rear flue exits
• Fully approved to OFTEC Standard and EC directives
• One year manufacturer’s warranty with five year guarantee
on boiler heat exchanger.

For a complete range of Grant  products call to Heatwise Tullamore.

or contact 0579351207.

Technical Information – Euroflame condensing economical outdoor oil boiler
OUTPUT
kW
OUTPUT
BTUs
FLOW
CONNECTION
RETURN
CONNECTION
COLD
MAINS
HOT
WATER
PRESSURE
RELIEF
CONDENSATE
PIPE
Outdoor Euroflame
50-70
15 – 21 50,000 – 70,000 22mm 22mm 21.5mm plastic overflow pipe
Outdoor Euroflame
70-90
21 – 26 70,000 – 90,000 22mm 22mm 21.5mm plastic overflow pipe
Outdoor Euroflame
90-120
26 – 36 90,000 – 120,000 22mm 22mm 21.5mm plastic overflow pipe
Dimensions
A
HEIGHT
B
WIDTH
C
DEPTH
Outdoor Euroflame 50-70 908 800* 505
Outdoor Euroflame 70-90 908 800* 505
Outdoor Euroflame 90-120 908 800* 505

Burner Settings

MODEL &
BURNER TYPE
HEAT OUTPUT
(kW)
HEAT OUTPUT
(BTU/h)
EFFICIENCY
NOZZLE
OIL
PRESSURE
SMOKE
NO.
BURNER
HEAD TYPE
BURNER HEAD /
DISC SETTING
FUEL FLOW
RATE (kg/h)
FLUEGAS TEMP.(°C)
CO2(%)
50/70 15.1 51500 0.50/80°EH 7 0 – 1 T1 B 1.29 70 – 75 11 – 12%
Reillo RDB2.2 *18.1 61750 93% 0.55/80°EH 7.5 0 – 1 T1 C 1.53 75 – 80 11 – 12%
20.7 70600 0.60/80°EH 8.5 0 – 1 T1 C 1.78 80 – 85 11 – 12%
70/90 20.7 70600 0.60/80°EH 8.5 0 – 1 T1 N/A 1.78 85 – 90 11 – 12%
Reillo RDB2.2 *22.7 77500 92.40% 0.65/80°EH 8.5 0 – 1 T2 N/A 1.95 85 – 90 11 – 12%
25.6 87350 0.75/80°EH 8 0 – 1 T2 N/A 2.19 90 – 95 11 – 12%
90/120 25.6 87350 0.75/80°EH 8 0 – 1 T2 N/A 2.19 75 – 80 11 – 12%
Reillo RDB2.2 *30.8 105100 92.10% 0.85/80°EH 9.1 0 – 1 T3 N/A 2.65 85 – 90 11 – 12%
34.7 118400 1.00/80°EH 8 0 – 1 T3 N/A 2.93 90 – 95 11 – 12%

*Factory Setting

Additional Information

Dimensions 80 × 50.5 × 90.8 cm